Welcome to our website!

+86-535-8088266      eric.chen@starkinstrument.cn              

Product Catalog
Contact Us
Mobile:+86-18663815259
Tel:+86-535-8088266
QQ:294772396
Email:eric.chen@starkinstrument.cn
Skype:jackie.chan-chemins
Add:No.18 Xiulin Rd, Laishan development zone, Yantai, China.
Whatsapp/Wechat: +86-18663815259

       

Name:YLG-2058 Industrial Online Residual Chlorine Analyzer
Measuring range:Residual chlorine: 0-20.00mg/L HOCL: 0-10.00mg/L pH value: 0 - 14.00pH Temperature: 0- 99.9 ℃
Accuracy:± 2% or ± 0.035mg/L
Signal output:4-20mA
Communication interface:Modbus RS485
Protection:IP65
Relay:AC 220V, 7A
Power supply:220VAC or DC24V

1. Measuring range      

Residual   chlorine: 0-20.00mg/L,      Resolution:   0.01mg/L;

HOCL: 0-10.00mg/L       Resolution: 0.01mg/L;

pH   value: 0 - 14.00pH        Resolution: 0.01pH;

Temperature: 0- 99.9 ℃          Resolution: 0.1 ℃

2. Accuracy: Residual   chlorine: ± 2% or ± 0.035mg / L, take the bigger;

HOCL: ± 2% or ± 0.035mg / L, take the   bigger;

pH   value: ± 0.05Ph

Temperature: ± 0.5 ℃ (0 ~ 60.0 ℃);

3.   Sample temperature: 0 ~ 60.0 ℃,   0.6MPa;


4. Sample flow rate: 200 ~250   mL/1min  Automatic and Adjustable

5.   Minimum detection limit: 0.01mg / L

6. Isolated current output: 4~20 mA(load <750Ω)

7. High and low alarm relays: AC220V, 7A;  

hysteresis 0- 5.00mg / L, arbitrary regulation

8. RS485 communication interface   (optional)

It can be convenient to computer   monitoring and communication

9. The data storage capacity: 1 month (1   point/5 minutes)

10. Power Supply: AC220V ± 22V, 50Hz ±   1Hz; DC24V (optional).

11. Protection grade: IP65

12. Overall dimension: 146 (length) x 146 (width) x 108 (depth)   mm;

dimension of the hole: 138 x 138mm

Note: The wall installation may be ok,   please specify when ordering.

13. Weight: Secondary Instrument: 0.8kg, flow cell with   residual chlorine,

pH electrode weight: 2.5kg;

14. Working Conditions: ambient   temperature: 0 ~ 60 ℃;  relative humidity <85%;

15.Adopt the flow-through installation,   inlet and outlet diameter at Φ10.

Note: The user can   select two-way current output; one way of residual chlorine corresponds to   current output, and the other way of optional pH or temperature corresponds   to the current output. The ex-factory standard configuration is that one way   of residual chlorine corresponds to the current output. Please specify when   ordering


English Display, English Menu operation: Easy operation, English prompts during the whole operational 

procedure ,convenient and quick.

Intelligent: It adopts high-precision AD conversion and single chip microcomputer processing technologies and can be used for the measurement of the PH values and temperature, automatic temperature compensation and self-checking etc function.

Multi-parameter display: On the same screen, residual chlorine, temperature, pH value, output current, status and time are displayed.

Isolated current output: Optoelectronic isolating technology is adopted. This meter has strong interference immunity and the capacity of long-distance transmission.

High and low alarm function: High and low alarm isolated output, hysteresis can be adjusted.


YLG-2058 Industrial Online Residual Chlorine Analyzer is a bran-new residual chlorine analyzer in our company; It is a high-intelligence on-line monitor, It is made up of three parts: a secondary instrument and a sensor, a organic glass flow cell. It can measure residual chlorine, pH and temperature simultaneously. It can be widely used for continuous monitoring of residual chlorine and pH value of various water quality in power, water plants, hospitals and other industries.


5332.jpg

Hits: 【Print】